View Issue Details

IDProjectCategoryView StatusLast Update
0000749T99X171.00 SKB EagleHW Issuepublic2021-12-23 17:23
Reporter(ALTech) SH Son Assigned To(PM) Sheila Tu Due Date2019-07-19 16:18
PriorityurgentSeveritys2-severeReproducibilityalways
Status closedResolutionopen 
Summary0000749: [BFX-AT100] “CH” printing is shifted over the Top housing.
DescriptionHi Sheila

Last 1K housing, “CH” printing is shifted over the Top housing.

So Please submit your manufacture's 8D report.

and next 9K production, "CH" printing should be located at center.

thanks
SON
TagsNo tags attached.
Attach Tags

Users monitoring this issue

User List (ALTech) BY Lee , (ALTech) JW Kim , (ALTech) Philip , (ALTech) SB Park , (ALTech) SH Son , (ALTech) SY Yoon

Activities

(ALTech) SH Son

2019-07-16 10:57

developer   ~0002834

@Sheila Tu

Could you please update this 8D report status?

(PM) Sheila Tu

2019-07-16 13:33

developer   ~0002835

I attached the 8D report from our vendor for your reference.

(ALTech) SH Son

2019-07-23 09:10

developer   ~0002846

@Sheila Tu
the 8D report is OK. I check root cause corrective actions.
one more things, at 2.Process Control b. The process is increased by 100% CCD inspection after pad printing .
 - Could you please send us CCD inspection test screen shot for BFX-AT100 housning? like as attached image.


ALT will be check and monitoring this "CH" printing issue. then close this issue.

Thank you for your support.

Thanks
SON
ccd.jpg (88,620 bytes)   
ccd.jpg (88,620 bytes)   

Issue History

Date Modified Username Field Change
2019-07-03 15:22 (ALTech) SH Son New Issue
2019-07-03 15:22 (ALTech) SH Son Status new => assigned
2019-07-03 15:22 (ALTech) SH Son Assigned To => (PM) Sheila Tu
2019-07-03 15:23 (ALTech) SH Son Issue Monitored: (ALTech) BY Lee
2019-07-03 15:23 (ALTech) SH Son Issue Monitored: (ALTech) JW Kim
2019-07-03 15:23 (ALTech) SH Son Issue Monitored: (ALTech) Philip
2019-07-03 15:23 (ALTech) SH Son Issue Monitored: (ALTech) SB Park
2019-07-03 15:23 (ALTech) SH Son Issue Monitored: (ALTech) SH Son
2019-07-03 15:23 (ALTech) SH Son Issue Monitored: (ALTech) SY Yoon
2019-07-16 10:57 (ALTech) SH Son Note Added: 0002834
2019-07-16 13:33 (PM) Sheila Tu File Added: 8D report for T99X171 top cover printing shift issue 190703.pdf
2019-07-16 13:33 (PM) Sheila Tu Note Added: 0002835
2019-07-23 09:10 (ALTech) SH Son File Added: ccd.jpg
2019-07-23 09:10 (ALTech) SH Son Note Added: 0002846
2021-12-23 17:23 (SW) Jacky Chiang Status assigned => closed